Hi all,

There is one sender mote and one receiver mote. When the receiver doesnot receive a certain packet, the cause may be no preamble detected or crc error. How can I distinguish these two causes?

I am currently using MicaZ sensor platform and TinyOS2.0.1. And I checked that by default CRC is verified by the Chipcon CC2420 hardware, but there is a metadata called crc. I also tried to retrieve this crc value from metadata. The only value I got is 1 even if there were packet losses, and it seems this method didnot work. Any other method to solve this problem?

Thanks a lot and kindly regards,

Shuo