Sorry, solved.. In fact, what I did solved the problem. I was just too impatient, and probably badly uploaded the program..
Best regards, Alban 2007/11/6, Alban Hessler <[EMAIL PROTECTED]>: > > Hi everybody, > > I wonder if someone has already use a MTS300 CB (the one with the nice > little green wire on their back). > > Using the pure tinyOS, I got only readings equal to zero. > > I modified PhotoTempDeviceC in the following way: > // TempControl.Power -> MicaBusC.Int2; > TempControl.Power -> MicaBusC.PW0; > > Since the power control pin of the mts300 cb is pw0, I thought my zero > nightmare would end here. > > But it only results in getting more zero values for the temperature > readings, and the it's extremly slow ! (a read call takes a few seconds). As > far as I could grep, PW0 is not used by any other resource (except > sensorboard mda100, but obviously, I am not wiring it). > Also, pin Int1 can conflict with int2/pw0 according to the mts300 > datasheet. People with CA boards have no problem, so it doesn't conflict > with int2, therefore it should not conflict with PW0 either.. > > Anybody had put his hands on that? I would really like know what is the > temperature here .. > > Thank you in advance, > > Alban Hessler > > >
_______________________________________________ Tinyos-help mailing list [email protected] https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help