Hello list, I am using Deluge T2 from the CVS on a tmote mini development kit board. I was having problems to inject a new program to the Golden image until I removed the base="983040" option from the golden image volume. I can now successfully inject to the golden image slot and ping to it but cannot perform the rollback. Whenever I reset the mote a few times it even blinks the LEDs 3 times before fading as in the normal boot sequence, but the program in execution doesn't change.
Besides that, I want to know if sending packets through the serial port during an inject are supposed to disrupt the process, as it appears to be happening. Thanks in advance, ~Dimas~