Hello list,

I am using Deluge T2 from the CVS on a tmote mini development kit board. I
was having problems to inject a new program to the Golden image until I
removed the  base="983040" option from the golden image volume. I can now
successfully inject to the golden image slot and ping to it but cannot
perform the rollback. Whenever I reset the mote a few times it even blinks
the LEDs 3 times before fading as in the normal boot sequence, but the
program in execution doesn't change.

Besides that, I want to know if sending packets through the serial port
during an inject are supposed to disrupt the process, as it appears to be
happening.

Thanks in advance,
~Dimas~