Hello Richard

You use the following component and wiring in the configuration:

components new SensirionSht11C() as Sht11;


App.Humedad -> Sht11.Humidity;

App.Temperatura -> Sht11.Temperature;



In the module:

module SHT11C

{

...

uses interface Read<uint16_t> as Humedad;

uses interface Read<uint16_t> as Temperatura; 

}

implementation

{

bool ReadHumedad = FALSE;

bool ReadTemperatura = FALSE;

uint16_t LecturaHumedad, LecturaTemperatura;

//Init the read of the sensor

if (call Humedad.read() != SUCCESS)

call Leds.led2Toggle(); // Mostrar error.

else ReadHumedad = TRUE;


if (call Temperatura.read() != SUCCESS)

call Leds.led2Toggle(); // Mostrar error.

else ReadTemperatura = TRUE;

//Events with the data

event void Humedad.readDone(error_t result, uint16_t data) 

{

uint16_t aux = data;

if (result != SUCCESS)

{

aux = 0xffff;

call Leds.led2Toggle(); // Mostrar error.

}

LecturaHumedad = aux;

ReadHumedad = FALSE;

atomic if(!ReadHumedad & !ReadTemperatura) post FuncionEnviarDatos();

}

event void Temperatura.readDone(error_t result, uint16_t data) 

{

uint16_t aux = data;

if (result != SUCCESS)

{

aux = 0xffff;

call Leds.led2Toggle(); // Mostrar error.

}

LecturaTemperatura = aux;

ReadTemperatura = FALSE;

atomic if(!ReadHumedad & !ReadTemperatura) post FuncionEnviarDatos();

}



I hope that help you.

A greeting,

Juan Antonio

  ----- Original Message ----- 
  From: Richard 
  To: [EMAIL PROTECTED] ; [EMAIL PROTECTED] 
  Cc: [email protected] 
  Sent: Friday, March 21, 2008 8:48 AM
  Subject: [Tinyos-help] how to activate built-in sensirion temp sensor intelosB


  Sir/Ma'am,


  May I ask your guidance and suggestion on how to make the temperature and 
humidity sensor of telosB work? I have difficulty in making it work. By the 
way, I already made the two other sensors (TSR and PAR) worked. But I cannot 
make the Humidity and Temperature sensor work in the telosB. Do I need to have 
Humidity.h file? Because in my case, the HumidityC.nc and HamamatsuC.nc which 
are used for Temperature/Humidity and TSR/PAR respectively are located in telos 
folder inside platform folder. Not in the telosb folder. Thank you.


  Richard


------------------------------------------------------------------------------
  Looking for last minute shopping deals? Find them fast with Yahoo! Search.


------------------------------------------------------------------------------


  _______________________________________________
  Tinyos-help mailing list
  [email protected]
  https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help
_______________________________________________
Tinyos-help mailing list
[email protected]
https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help