Dear Philip,
   
  Thank you for your replay.
   
  In Blink application under app/ directory:
  Timer0 fire every 0.023 s (at average) while it should fire every 0.25 s
  Timer1 fire every 0.046 s (at average) while it should fire every 0.5 s 
  Timer2 fire every 0.09 s (at average) while it should fire every 1 s
   
  Also, in BlinkTask application under app/tutorial directory:
  Timer0 fire every 0.038 s (at average) while it should fire every one second.
   
  The last one I have tested is Sense application under app/ directory:
  Timer fire every 0.019 s (at average) while it should fire every 0.1 s.
   
  I am using Tinyos 2.x under xubuntu. To run the simulater, I used the 
standard variables.py example script.
   
  I am now working on timing analysis for nesC application under TOSSIM. But 
with these results I don’t know how I can get an accurate statistics.
   
  Regards,
  Mustafa


Philip Levis <[EMAIL PROTECTED]> wrote:  =On Apr 6, 2008, at 5:08 PM, Mustafa 
Hammad wrote:
> Hi all,
>
> I have noticed that, in TOSSIM execution, the firing interval for a 
> timer is different from what it is set for.
>
> Has anybody experienced the same problem?
> Any commend will be appreciated.
>
> Thanks,
> Mustafa
>

Can you be more specific? I.e., show a simple application test case 
that triggers this, and the output you observe? If it's not 
reproducible, then it's hard to help. From the descriptions so far, 
the problem could be anything from a bug in your code, to a 
misconception of how TOSSIM works, to a problem with TOSSIM itself.

Phil


       
---------------------------------