Are they connected in the config file?
MS

Nicola Wegner wrote:
> Hi,
> 
> I have a module that uses and provides the interface Mount:
>      uses interface Mount as UsedMount;
>      provides interface Mount as ProvidedMount;
> 
> The implementation of ProvidedMount.mount() looks like this:
>      command error_t ProvidedMount.mount() {
>           return call UsedMount.mount();
>      }
> 
> I think this should be possible but I get the following error:
>      PermConfStorageP.nc: In function `ProvidedMount.mount':
>      PermConfStorageP.nc:72: UsedMount.mount not connected
> 
> Without the call UsedMount.mount() it compiles. I can even call 
> UsedMount.mount() somewhere else in the code and it works.
> 
> Any explanations for this behavior?
> 
> Thanks Nicola
> 
> 
> ------------------------------------------------------------------------
> 
> _______________________________________________
> Tinyos-help mailing list
> [email protected]
> https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help

-- 
Platform: WinXP/Cygwin
TinyOS version: 1.x, Boomerang
Programmer: MIB510
Device(s): Mica2, MicaZ, Tmote
Sensor board: homebrew

_______________________________________________
Tinyos-help mailing list
[email protected]
https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help

Reply via email to