Hello Sir, I am using iris platform motes with MDA 300 board. I am implementing modbus communication inside the gateway. I succeeded to implementing modbus holding register. ie now my gateway is able to communicate with the hardware or software that support modbus interface directly. Now i want to implement command of motes such as sleep,wake accutate ... through modbus write function such as function 10. But i have problem with xcommand data format, how to broadcast that message. Any how i got the message format of command sleep for Mote 1.Please refer the wiring diagram of motes. In this wiring diagram i am not using UARTFramedPacket.nc,FramerAckM.nc,FramerM,UART,UARTM component and module instead of these component and module i used ModbusC,ModbusM module.
For sending xcommand message from serial port i am doing following steps 1. store the Xcommand data into uint8_t array[33]; 2. store the address of array into TOS_MsgPtr TOS_MsgPtr Arrayptr=(TOS_MsgPtr)array; send this Arrayptr to AMpromiscuous event ReceiveMsg.receive(TOS_MsgPtr ptr); by signal ReceiveMsg.receive(ArrayPtr); *Note : Same data packet i stored in array[33] which is used by xserve for sending xcommand* Please tell me 1)Is it correct step of sending xcommand ? if any step i am not doing then tell me. 2) i am not using UARTFramedPacket.nc,FramerAckM.nc,FramerM,UART,UARTM component due to this whether i need to change data format of xcommand used by xserve ? if yes then tell me correct format. I am attaching both default one and my own component diagram of Xmeshbase. Please see it and if you have any solution then please share with me. -- Regards Ravish Kumar
_______________________________________________ Tinyos-help mailing list [email protected] https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help