Hi guys, I am using MIB520, MDA300 and two micaZs to form a simple mote that sends data to my pc. I am facing a problem whereby my mote sends data after every 2 seconds. my intention is to program micaZ so that it would send readings from MDA300 every 1 minute when the input to ADC2 is >2.0 volts, and every 2 minutes when the input to ADC2 is <2.0 volts.
I am using Programmer's Notepad 2 to modify the file XMDA300M.nc. And i noticed that the supporting file sensorboardApp.h has the following lines in the end of its program "... #ifdef APP_RATE uint32_t XSENSOR_SAMPLE_RATE = APP_RATE; #else #ifdef USE_LOW_POWER uint32_t XSENSOR_SAMPLE_RATE = 184320; #else uint32_t XSENSOR_SAMPLE_RATE = 1843; #endif #endif uint32_t timer_rate; ..." which might explain why my mote sends back data every 2 seconds. how can i modify codings of both or either one files to achieve my desired sampling pattern ? your help is very much appreciated. Thank you. Best Regards, Alvin