Hi everybody 
 
the User guide for MSP430XX 
http://focus.ti.com/lit/ug/slau056g/slau056g.pdf 
  
described the SVS 
  
The supply voltage supervisor (SVS) is used to monitor the AVCC supply 
voltage or an external voltage. The SVS can be configured to set a flag or 
generate a POR reset when the supply voltage or external voltage drops below 
a user-selected threshold. 
The SVS features include: 
AVCC monitoring 
Selectable generation of POR 
Output of SVS comparator accessible by software 
Low-voltage condition latched and accessible by software 
14 selectable threshold levels 
External channel to monitor external voltage
 
SVS Operation 
The SVS detects if the AVCC voltage drops below a selectable level. It can be 
configured to provide a POR or set a flag, when a low-voltage condition occurs. 
The SVS is disabled after a POR to conserve current consumption
 
concerning my question about using an external DC voltage source and the mote 
stop responding if the voltage is lower than 2V.
can I configure this value in my mote to change the lower value ?


      
_______________________________________________
Tinyos-help mailing list
[email protected]
https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help

Reply via email to