Hi! Use the RF230 sniffer application from tinyos 2.x: apps/tests/rf230/RF230Sniffer
Miklos On Mon, May 11, 2009 at 7:16 PM, KUNYOUNG LEE <[email protected]> wrote: > Dear Engineer. > > Recently, I carry out communication simulation using the MoteWorks version > based IRIS platform that > one node broadcasts its packet (size: 132 bytes) after the timer expires > (duration : 100ms) and it continues repeatedly. > > As I cannot find the reason of problem which I met, I send e-mail to you for > your help. > > When I determine sequence number and received time of broadcasted packets > using Xniffer, > I confirm the fact that successive packets have successive sequence number > but their received times sometimes are identical each other. > (Xniffer is provided by the Crossbow and is included by the MoteWorks > software version.) > > I guess that Xniffer processing time does not cover the speedĀ because a > node broadcasts its packet every nearly 100ms. > > I hope to know the exact reason. > > I wait for your e-mail. > Thank you for your help. > > Best Regards, > KUNYOUNG LEE > > > _______________________________________________ > Tinyos-help mailing list > [email protected] > https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help > _______________________________________________ Tinyos-help mailing list [email protected] https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help