Thanks. I think I got the idea. One missing piece is how to read the Tx power. Do you have an interface to recommend?
David On Wed, May 20, 2009 at 2:20 PM, Miklos Maroti <[email protected]>wrote: > Hi David, > > On Wed, May 20, 2009 at 11:15 PM, David Li <[email protected]> wrote: > > Hi Miklos, > > I plan to use the tutorial code in Oscope. So I think it uses message_t. > Is > > this what you are asking? Please explain what you meant by "manually". Do > > you have an example? > > Ok, look at OscilloscopeC.nc, we copy the local structure into the > message_t and send it. The local structure is of oscilloscope_t type. > You need to add another field to oscilloscope_t, fill it up with the > TX power you use to send the message, then modify the java to > recognize that extra field. > > What I am saying that any extra information can be put into a message. > TX_PWR is no different, but you have to write the code to put it > there. > > Miklos >
_______________________________________________ Tinyos-help mailing list [email protected] https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help