1>Setup detail :- Total number of motes used = 4 Base station = 1 no.s Id 0 Co-ordinator =1 no.s Id 1 Remote mote’s = 2 no.s Id 2 & 3 2>Version and Hardware details :- Cygwin - 2.0.5 version (tinyos) Sensorboard – SBT80 Mote’s – Moteiv Tmote Sky 3>Problem details :- In our mote’s we have modified code of SBT80app in which we have added functionality of RSSI and Receive function . In Base station we have used TOSBASE code in it. As the demo starts we see that mote with Id 1 (co-ordinator) receive data from other two mote’s in the remote network and send it to PC via Base station for display and we see that only Id 1 sensor readings are available and rest two remote mote’s sensor readings are missing but Id , Sequence number , RSSI , start bit and end bit CRC is coming proper . 4>Solution what I want :- I am losing data of sensors but as I can receive start and stop bit CRC properly along with other details like Id , Sequence number , RSSI . so is there any way out for distributing data and address separate in the payload received . so that I can come to know about the mistake and can read the sensor readings. Does cygwin supports step wise compilation .
-- Regards Akashdeep Singh Sodhi Embedded Software Engineer Mumbai 09819894870
_______________________________________________ Tinyos-help mailing list [email protected] https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help