I'm using the tinyos-2.1.0 and mica2. In the Oscilloscope,when I change the DEFAULT_INTERVAL into a smaller integral ,like 20,then the sink mote(running BaseStation) can't receive the message correctly,what's the reason and how can I solve it. Does the sampling period have a lower bound and the mote can't receive the messages correcting when the sampling period is lower than it? Thanks very much. the data the PC receive: 00 FF FF 00 01 1C 00 93 00 00 00 19 00 01 00 01 01 AA 01 AA 01 AB 01 AB 01 AA 01 AB 01 AB 01 AA 01 AA 01 AA 00 FF FF 00 01 1C 00 93 00 00 00 19 00 01 00 02 01 AB 01 AA 01 AA 01 AA 01 AA 01 AA 01 AA 01 AB 01 AA 01 AA
packet lost 00 FF FF 00 01 1C 00 93 00 00 00 19 00 01 00 04 01 AB 01 AB 01 AA 01 AA 01 AA 01 AA 01 AA 01 AB 01 AA 01 AA 00 FF FF 00 01 1C 00 93 00 00 00 19 00 01 00 05 01 AA 01 AA 01 AA 01 AB 01 AA 01 AA 01 AA 01 AB 01 AB 01 AA 00 FF FF 00 01 1C 00 93 00 00 00 19 00 01 00 06 01 AA 01 AA 01 AA 01 AA 01 AA 01 AA 01 AB 01 AA 01 AA 01 AA 00 FF FF 00 01 1C 00 93 00 00 00 19 00 01 00 07 01 AB 01 AB 01 AB 01 AB 01 AB 01 AB 01 AA 01 AA 01 AA 01 AB 00 FF FF 00 01 1C 00 93 00 00 00 19 00 01 00 08 01 AB 01 AA 01 AB 01 AA 01 AA 01 AB 01 AB 01 AA 01 AA 01 AA 00 FF FF 00 01 1C 00 93 00 00 00 19 00 01 00 09 01 AA 01 AA 01 AB 01 AA 01 AA 01 AA 01 AB 01 AB 01 AB 01 AB 00 FF FF 00 01 1C 00 93 00 00 00 19 00 01 00 0A 01 AB 01 AB 01 AB 01 AB 01 AA 01 AA 01 AA 01 AA 01 AA 01 AA 00 FF FF 00 01 1C 00 93 00 00 00 19 00 01 00 0B 01 AA 01 AA 01 AB 01 AA 01 AB 01 AA 01 AB 01 AB 01 AA 01 AB 00 FF FF 00 01 1C 00 93 00 00 00 19 00 01 00 0C 01 AB 01 AB 01 AA 01 AA 01 AA 01 AA 01 AA 01 AA 01 AA 01 AA 00 FF FF 00 01 1C 00 93 00 00 00 19 00 01 00 0D 01 AB 01 AA 01 AB 01 AA 01 AB 01 AA 01 AA 01 AA 01 AA 01 AA 00 FF FF 00 01 1C 00 93 00 00 00 19 00 01 00 0E 01 AB 01 AB 01 AA 01 AA 01 AA 01 AA 01 AA 01 AA 01 AA 01 AA 00 FF FF 00 01 1C 00 93 00 00 00 19 00 01 00 0F 01 AA 01 AA 01 AA 01 AA 01 AB 01 AA 01 AB 01 AA 01 AA 01 AA 00 FF FF 00 01 1C 00 93 00 00 00 19 00 01 00 10 01 AA 01 AA 01 AB 01 AA 01 AA 01 AB 01 AB 01 AA 01 AA 01 AA 00 FF FF 00 01 1C 00 93 00 00 00 19 00 01 00 11 01 AB 01 AA 01 AB 01 AB 01 AB 01 AA 01 AB 01 AB 01 AA 01 AA packet lost 00 FF FF 00 01 1C 00 93 00 00 00 19 00 01 00 13 01 AA 01 AA 01 AB 01 AA 01 AA 01 AB 01 AB 01 AA 01 AB 01 AB 00 FF FF 00 01 1C 00 93 00 00 00 19 00 01 00 14 01 AB 01 AA 01 AB 01 AB 01 AA 01 AA 01 AB 01 AB 01 AA 01 AA 00 FF FF 00 01 1C 00 93 00 00 00 19 00 01 00 15 01 AB 01 AA 01 AA 01 AB 01 AA 01 AA 01 AA 01 AB 01 AB 01 AA 00 FF FF 00 01 1C 00 93 00 00 00 19 00 01 00 16 01 AB 01 AA 01 AA 01 AA 01 AA 01 AA 01 AA 01 AA 01 AA 01 AA 00 FF FF 00 01 1C 00 93 00 00 00 19 00 01 00 17 01 AB 01 AA 01 AA 01 AA 01 AA 01 AA 01 AA 01 AB 01 AA 01 AB 00 FF FF 00 01 1C 00 93 00 00 00 19 00 01 00 18 01 AB 01 AA 01 AA 01 AA 01 AA 01 AA 01 AA 01 AA 01 AA 01 AA packet lost 00 FF FF 00 01 1C 00 93 00 00 00 19 00 01 00 1B 01 AA 01 AA 01 AA 01 AA 01 AB 01 AA 01 AA 01 AB 01 AA 01 AA 00 FF FF 00 01 1C 00 93 00 00 00 19 00 01 00 1C 01 AB 01 AA 01 AA 01 AA 01 AA 01 AA 01 AA 01 AA 01 AA 01 AA 00 FF FF 00 01 1C 00 93 00 00 00 19 00 01 00 1D 01 AA 01 AA 01 AB 01 AB 01 AB 01 AB 01 AB 01 AA 01 AB 01 AB 00 FF FF 00 01 1C 00 93 00 00 00 19 00 01 00 1E 01 AA 01 AB 01 AA 01 AA 01 AA 01 AB 01 AA 01 AB 01 AA 01 AA 00 FF FF 00 01 1C 00 93 00 00 00 19 00 01 00 1F 01 AB 01 AA 01 AA 01 AA 01 AB 01 AB 01 AB 01 AB 01 AB 01 AB 00 FF FF 00 01 1C 00 93 00 00 00 19 00 01 00 20 01 AB 01 AC 01 AA 01 AA 01 AA 01 AA 01 AA 01 AA 01 AA 01 AA
_______________________________________________ Tinyos-help mailing list [email protected] https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help