On Mon, Dec 7, 2009 at 12:23 AM, Group <[email protected]> wrote: > Hi, > > I have some basic question on running MultihopOscilloscope. > I have 3 motes. One connected to PC with moteID 1 and other > two with moteids 2,3 are powered with battery. All of them have > MultiHopOscilloscope running. When i ran sf and oscilloscope > application on PC by following commands in README.txt. > I didnot find any messages. Do i need to give any topology file?. > I'm not sure whether this is the right way to run the application. > Please let me know if i'm missing something.Thanks.
Here is an excerpt from README.txt "Notes: MultihopOscilloscope configures a mote whose TOS_NODE_ID modulo 500 is zero to be a collection root." You need to program the node id of the root (mote connected with the base station) following this guideline. - om_p _______________________________________________ Tinyos-help mailing list [email protected] https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help