Hi Jeena, If you are using an unmodified version of TestFTSP, then the units will be milliseconds. The TelosB motes are not capable of microsecond time synchronization accuracies out of stock, since they don't have a stable microsecond time source.
What you can do though is switch over to the T32khz timers. This will at least give you 30.5us accuracy. Cheers, Thomas On Thu, Dec 17, 2009 at 5:45 AM, Jeena Sebastian <[email protected]> wrote: > I'm working on time synchronization of TelosB motes. In this regard, I've > been trying to understand the implementation of FTSP via the TestFTSP > application. > > In TestFtsp I have a doubt as to what is the unit of time for reporting time > sync errors. Is it in milli seconds or micro seconds ? I am attaching the > graph along with this mail. Can anyone please throw some light on this. I am > generating the graph as per the matlab code available in TestFtsp > application. > > Any help in this regard will be highly appreciated. > > Regards, > Jeena > > _______________________________________________ > Tinyos-help mailing list > [email protected] > https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help > _______________________________________________ Tinyos-help mailing list [email protected] https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help