Content preview:  Hi: I've made some test boards using msp430f1611 and cc2500
   ,but the blinkToRadio example can not work on my two boards. I have double
   checked the wire connection between mcu and my cc2500 module. The data seems
   have been sent out because the sendDone signaled. But the receive.receive
   can not receive anything.If i change the timerMILLI to 700 ms , then i can
   see the mcu has read cc2500 RX_FIFO(the node_id, the counter and some other
   about bytes i do not know) , but the Receive.receive still can not be 
signaled.
   I tried to change the PA value ,still nothing happen,can you help me out?
   [...] 

Content analysis details:   (4.3 points, 3.3 required)

 pts rule name              description
---- ---------------------- --------------------------------------------------
 3.2 FH_DATE_PAST_20XX      The date is grossly in the future.
 0.0 HTML_MESSAGE           BODY: HTML included in message
 0.0 BAYES_50               BODY: Bayesian spam probability is 40 to 60%
                            [score: 0.5000]
 1.1 DNS_FROM_OPENWHOIS     RBL: Envelope sender listed in bl.open-whois.org.

The original message was not completely plain text, and may be unsafe to
open with some email clients; in particular, it may contain a virus,
or confirm that your address can receive spam.  If you wish to view
it, it may be safer to save it to a file and open it with an editor.

--- Begin Message ---
Hi:
   I've made some test boards using msp430f1611 and cc2500 ,but the 
blinkToRadio example can not work on my two boards. I have double checked the 
wire connection between mcu and my cc2500 module. The data seems have been sent 
out because the sendDone signaled. But the receive.receive can not receive 
anything.If i change the timerMILLI to 700 ms , then i can see the mcu has read 
cc2500 RX_FIFO(the node_id, the counter and some other about bytes i do not 
know) , but the Receive.receive still can not be signaled. I tried to change 
the PA value ,still nothing happen,can you help me out?
 