Hello,

I'm playing around with the TestFtsp application with MicaZ platform, and
tested both milli and 32k versions. I would like to know if it possible to
use the microsecond resolution so I can get the time sync error exactly as
much as possible. I found out that CC2420TimeSyncMessageC component does not
offer the microsecond interface and I'm wondering if the radio can support
it. If it is possible, what changes can I make?

Based on my tests on TestFtsp using 32k time, I found out that the average
time synchronization error between to MicaZs is close to millisecond. I have
also read the paper on FTSP and it claims that it has an average time sync
error within microsecond. Can I know if there is any modifications that I
must do to reach that microsecond error? Or am I just currently doing
something wrong?

Thanks for the help.

JC de Dios
University of the Philippines
_______________________________________________
Tinyos-help mailing list
[email protected]
https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help

Reply via email to