On Fri, Apr 15, 2011 at 3:08 PM, Sherlock <pratikpatil0...@gmail.com> wrote: > > Hello everyone, > > In multihoposcilloscope application, suppose I have three nodes and I want > to check the hop by hop working of this application. So how should I go > about it? The readme.txt is not very much clear. Should I put ids to nodes > as say > 0(BaseStation), 1, and 2 for sensing some data OR the multihop base station > should not be used for serial communication with pc and another separate > node should be programmed BaseStation application. > > When i tried to keep program one node with id 1(with multihop app), second > with 0(with multihop app) and last with BaseStation, then SerialForwareder > is working but java gui of Oscilloscope app is showing nothing.
You should install the MultihopOscilloscope app with id 0, 1, and 2. No need to install the BaseStation app. - om_p _______________________________________________ Tinyos-help mailing list Tinyos-help@millennium.berkeley.edu https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help