Hi,

I don't understand what are the "entities" you mention. To get RSSI on CC2420-
based nodes, you can call the CC2420Packet.getRssi function. The offset to
transform the raw value to dBm should be esperimentally determined, but it is
approximately -45. Thus, if getRssi returns -10, the RF input power is
approximtely -10-45 = -55 dBm. Please refer to CC2420 datasheet for more
details.

Regards,
  Giuseppe

On Wednesday 18 May 2011 10:26:22 Lyubomir Ivanov wrote:
>  Does someone know how to convert the raw values of the read rssi values
> into dBms. I know that if you want get the rssi with get.rssi it is
> supposed to extract 45 entities, but I don't know how entities must be
> substract when using ReadRssi!

--
Giuseppe Cardone, Ph.D. Student
DEIS-LIA - University of Bologna
E-mail: [email protected]
Web: http://lia.deis.unibo.it/Staff/GiuseppeCardone/

LA RICERCA C’È E SI VEDE:
5 per mille all'Università di Bologna - C.F.: 80007010376