I use Iris Mote and MDA100CB development area.

George_1985 wrote:
> 
> With all this i mean that , i want to get the right ADC channel , sample
> the value , store it in a struct and send it to Base and then to pc.
> 
> 
> George_1985 wrote:
>> 
>> Hi , i use Tinyos-2..
>> 
>> I want to read humidity data from EC-5 soil sensor.
>> i want to read values from adc with SendingMote (RssiDemo) ,using also
>> compoment MicaBusC.
>> 
>> I have already motify the code but i i think need some help here.
>> 
>> New lines  
>> 
>> 
>> SendingMoteC.nc
>> 
>> #include "ApplicationDefinitions.h"
>> #include "RssiDemoMessages.h"
>> 
>> module SendingMoteC {
>>   uses interface Boot;
>>   uses interface Timer<TMilli> as SendTimer;
>>   uses interface GeneralIO as PW1;
>>   uses interface MicaBusAdc as Adc7
>>   
>>   uses interface AMSend as RssiMsgSend;
>>   uses interface SplitControl as RadioControl;
>> } implementation {
>>   message_t msg;
>>   
>>   event void Boot.booted(){
>>     call RadioControl.start();
>>     call PW1.makeOutput();
>>   }
>>   event void RadioControl.startDone(error_t result){
>>     call SendTimer.startPeriodic(SEND_INTERVAL_MS);
>>   }
>>   event void RadioControl.stopDone(error_t result){}
>> 
>>   event void SendTimer.fired(){
>>     
>>     call Adc7.getChannel();
>> 
>>     call RssiMsgSend.send(AM_BROADCAST_ADDR, &msg, sizeof(RssiMsg));    
>>     call PW1.toggle();    
>>   }
>>   event void RssiMsgSend.sendDone(message_t *m, error_t error){}
>> }
>> 
>> Thank you.
>> 
> 
> 

-- 
View this message in context: 
http://old.nabble.com/Read-Adc---humidity-value-tp31655696p31658449.html
Sent from the TinyOS - Help mailing list archive at Nabble.com.

_______________________________________________
Tinyos-help mailing list
[email protected]
https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help

Reply via email to