Hi Alejandro, Your code seems all right, the problem is with your expectation. The reading from the sensor is 0x19E2. I don't understand why do you expect such long message.
Andris On Fri, Feb 10, 2012 at 10:09 PM, <[email protected]> wrote: > Hello. > > I am using a telosb mote, and I'm trying to send the Temperature value > from a node(With my app attached) to an other (with BaseStation app). > > I guided from the BlinkToRadio app, but also add the interface Read to get > the Temperature sensor from SensirionSht11C. > > The application is compiling without error, but when I try to see the raw > data in my terminal through this command: > > java net.tinyos.tools.Listen -comm serial@/dev/ttyUSB1:telosb > > Only I see: > > serial@/dev/ttyUSB1:115200: resynchronising > 00 FF FF 00 08 04 22 06 00 08 19 E2 > 00 FF FF 00 08 04 22 06 00 08 19 E2 > 00 FF FF 00 08 04 22 06 00 08 19 E2 > > Which is very similar that shows BlinkToRadio > > However, I am expecting something like this: > > 00 FF FF 00 00 1C 00 64 32 37 20 20 0A 00 00 00 00 00 00 00 00 00 00 00 00 > 00 00 00 00 00 00 00 00 00 00 00 > 00 FF FF 00 00 1C 00 64 32 37 20 20 0A 00 00 00 00 00 00 00 00 00 00 00 00 > 00 00 00 00 00 00 00 00 00 00 00 > 00 FF FF 00 00 1C 00 64 32 37 20 20 0A 00 00 00 00 00 00 00 00 00 00 00 00 > 00 00 00 00 00 00 00 00 00 00 00 > 00 FF FF 00 00 1C 00 64 32 37 20 20 0A 00 00 00 00 00 00 00 00 00 00 00 00 > 00 00 00 00 00 00 00 00 00 00 00 > > > Please someone could give an advice to fix it? > > Thanks in advance. > > Regards, > > Alejandro. > _______________________________________________ > Tinyos-help mailing list > [email protected] > https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help _______________________________________________ Tinyos-help mailing list [email protected] https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help