This is a question that you can easily answer yourself simply by reading the code.
Look at OscilloscopeC.nc and understand what it is doing with Timer<TMilli>. This is basic nesC/TinyOS programming. On Wed, Jan 30, 2013 at 9:18 PM, Muhammad Arslan <[email protected] > wrote: > Hello, > I am using Telosb motes to sense temperature reading from it. > Can any one please tell me, how should i increase the interval of a > reading. > As now, Oscilloscope is giving me reading after every second, > I question whether that is true. From my very quick perusal of the code it looks like the timer is programmed for 256 mis (binary milliseconds). Unless it is aggragating 4 intervals then it should be taking a sample every 1/4 second. There are 1024 mis in 1second. TinyOS typically uses binary time. Convoluted story. > i want to program so that it > give me reading after 1 min. > > _______________________________________________ > Tinyos-help mailing list > [email protected] > https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help > -- Eric B. Decker Senior (over 50 :-) Researcher
_______________________________________________ Tinyos-help mailing list [email protected] https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help