This is a question that you can easily answer yourself simply by reading
the code.

Look at OscilloscopeC.nc and understand what it is doing with Timer<TMilli>.

This is basic nesC/TinyOS programming.

On Wed, Jan 30, 2013 at 9:18 PM, Muhammad Arslan <[email protected]
> wrote:

> Hello,
> I am using Telosb motes to sense temperature reading from it.
> Can any one please tell me, how should i increase the interval of a
> reading.
> As now, Oscilloscope is giving me reading after every second,
>

I question whether that is true.   From my very quick perusal of the code
it looks like the timer
is programmed for 256 mis (binary milliseconds).   Unless it is aggragating
4 intervals then it
should be taking a sample every 1/4 second.   There are 1024 mis in
1second.   TinyOS typically
uses binary time.   Convoluted story.


> i want to program so that it
> give me reading after 1 min.
>
> _______________________________________________
> Tinyos-help mailing list
> [email protected]
> https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help
>



-- 
Eric B. Decker
Senior (over 50 :-) Researcher
_______________________________________________
Tinyos-help mailing list
[email protected]
https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help