Hi, I'm working on remotely upgrading the application code within our MSP430F2616 based board.
Does anyone have an example of how to download a new executable and reboot from the new location in flash. We are using the MSP430F2616 chip, TinyOS and nesC; and I was hoping to split the flash code memory in two. So that once the new code has been received and validated, the start code pointer (and maybe vector values) are modified so that when a reboot is invoked the new code would be used. I have been looking at various documentation but I have not been successful in finding out whether this is possible. If it is; what registers need to be modified? Any help would be really appreciated. Thanks Alan Doyle
_______________________________________________ Tinyos-help mailing list [email protected] https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help