Hi Leon, Max message length when TIPC is used in message oriented mode (i.e., SOCK_DGRAM, SOCK_RDM, SOCK_SEQPACKET) is 66000 bytes. When you are using stream mode (SOCK_STREAM) it is the maximum of a signed integer (just like in TCP).
BR ///jon > -----Original Message----- > From: Leon Pollak [mailto:le...@plris.com] > Sent: Monday, 28 March, 2016 04:48 > To: tipc-discussion@lists.sourceforge.net > Subject: [tipc-discussion] Max msg length > > Hello, all. > > I tried to understand what is the maximum TIPC message length allowed. > > I found version 1.7 manual saying that 66000 bytes is the upper limit. But > this number seemed to me strange and I continued to search. > And I found TIPC discussion saying: "...as the maximum length of one TIPC > message never exceeds the maximum of signed integer". ------------------------------------------------------------------------------ Transform Data into Opportunity. Accelerate data analysis in your applications with Intel Data Analytics Acceleration Library. Click to learn more. http://pubads.g.doubleclick.net/gampad/clk?id=278785471&iu=/4140 _______________________________________________ tipc-discussion mailing list tipc-discussion@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/tipc-discussion