Hi Leon,
Max message length when TIPC is used in message oriented mode (i.e., 
SOCK_DGRAM, SOCK_RDM, SOCK_SEQPACKET) is 66000 bytes. When you are using stream 
mode (SOCK_STREAM) it is the maximum of a signed integer (just like in TCP).

BR
///jon


> -----Original Message-----
> From: Leon Pollak [mailto:le...@plris.com]
> Sent: Monday, 28 March, 2016 04:48
> To: tipc-discussion@lists.sourceforge.net
> Subject: [tipc-discussion] Max msg length
> 
> Hello, all.
> 
> I tried to understand what is the maximum TIPC message length allowed.
> 
> I found version 1.7 manual saying that 66000 bytes is the upper limit. But
> this number seemed to me strange and I continued to search.
> And I found TIPC discussion saying: "...as the maximum length of one TIPC
> message never exceeds the maximum of signed integer".

------------------------------------------------------------------------------