On Mon, Apr 18, 2011 at 4:11 PM, Bruce <[email protected]> wrote: > I have a MFJ-259B VSWR analyzer that the reactance is no longer X=0, but > X=5 when a pure resistive 50 ohm load is attached. Makes spring time > checking of low band antennas more difficult. Anyone know which control pot > is used to zero the meter reactance reading when no reactance is present?. > 73 > Bruce >
Bruce, here are the calibration instructions from the guy who designed it for MFJ. http://www.w8ji.com/mfj-259b_calibration.htm 73 Mike www.w0btu.com _______________________________________________ UR RST IS ... ... ..9 QSB QSB - hw? BK