On Mon, Apr 18, 2011 at 4:11 PM, Bruce <[email protected]> wrote:

> I have a MFJ-259B VSWR analyzer that the reactance is no longer X=0, but
> X=5 when a pure resistive 50 ohm load is attached. Makes spring time
> checking of low band antennas more difficult. Anyone know which control pot
> is used to zero the meter reactance reading when no reactance is present?.
> 73
> Bruce
>

Bruce, here are the calibration instructions from the guy who designed it
for MFJ.

http://www.w8ji.com/mfj-259b_calibration.htm

73 Mike
www.w0btu.com
_______________________________________________
UR RST IS ... ... ..9 QSB QSB - hw? BK

Reply via email to