> Excuse me but dielectric loss is what determines Q and in this case it > is synonomous with capacitance. Conductor loss is lower also.
Dielectric loss of polyethylene coax at HF is negligible. A lower dielectric constant does reduce conductor losses, so lower capacitance corresponds to lower losses, but only if the construction is otherwise identical. Coax that is much larger in diameter will have lower losses than small coax even if it has more capacitance. Rick N6RK _______________________________________________ UR RST IS ... ... ..9 QSB QSB - hw? BK