I shunt feed my tower for topband. I use variable vacuum caps and a vacuum relay at the base to switch between the low end and the high end of the band. It seems to work okay. I have 100' buried radials spaced 10' at the ends from o degrees going clockwise through about 220 degrees. I have a 4' high stone wall that runs about 20/200 degrees that is about 35' at its closest point to the tower. So the radials are progressively shorter on the West side of the tower.
I am making an assumption that going up over the wall will distort any benefits of extending the radials on the West side? Is that a true assumption. I can't really have the radials go from the tower base up at an angle to clear the stone wall and continue on. If I am to extend them the radials would have to go on the ground to the wall then up and over and back down to the ground. 73, N2TK, Tony _______________________________________________ UR RST IS ... ... ..9 QSB QSB - hw? BK