Good point Mike, but I am hoping someone has done definitive testing between insulated and un-insulated wire concerning voltage build up. If the voltage
is lower with insulated wire there is less to bleed off, and possibly lower
noise activity.

http://www.qsl.net/k1fz/beveragenotes.html

73 Bruce-K1FZ




----- Original Message -----
From: "Mike Waters" <[email protected]>
To: "topband" <[email protected]>
Sent: Thursday, November 15, 2012 9:56 AM
Subject: Re: Topband: Covered /bare antennn wire


Why not prevent the static buildup in the first place? I use 33K resistors
from each wire to ground. Schematic is at
http://www.w0btu.com/Beverage_antennas.html .

The components in parallel with the 33K resistors are 90 volt gas discharge
tubes, and the resistors are to prolong the life of those GDTs.

73, Mike
www.w0btu.com
_______________________________________________
Topband reflector - [email protected]



_______________________________________________
Topband reflector - [email protected]

Reply via email to