What is the real or best guess what value this inductor has? This is what I am using.
Edge wound coil is 1/2 inch wide, 1/32 inch thick stock, coil is 2 1/2 inches long,15 turns, 4.5” ID, 5.5” OD transmit tap is at 9 turns, 6 turns remain going to antenna. Inductance calculations were found here http://www.66pacific.com/calculators/coil_calc.aspx<%22http://www.66pacific.com/calculators/coil> Total inductance is 29.6uH, 9 turns = 12.7uH, 6 turns = 6.7 uH, 6 turns = 7.9 feet. If you wound a coil with 1/8 inch or 1/4 inch copper tubing , is there any online calculator that can give you a good answer on its value? -- Jim K9TF _________________ Topband Reflector