Kevin

How long a run we talking here?

Dave
NR1DX

On 9/19/2019 11:17 AM, Kevin Shea via Topband wrote:
I have read that the skin effect at 2 MHz may be deeper than the copper coating 
on a copper covered steel inner conductor of most RG6 cables.� Thus, as I plan 
for long cable runs back from my (to be installed) Beverages I am thinking I 
need either solid copper, solid aluminum,. or copper covered aluminum for my 
RG6 coax.� So the question is am I wrong in this understanding?
Also, does the shield matter?� It's not very thick so does a foil and 60% 
aluminum shield do the job?� Or should I be looking at a foil and 95 percent 
copper shield like the Belden 1694.
I know it may not be too material but I want to make an informed decision.
Thanks! and
73,
Kevin, N9JKP
_________________
Searchable Archives: http://www.contesting.com/_topband - Topband Reflector

--
Dave
[email protected]
www.ArtekManuals.com


---
This email has been checked for viruses by Avast antivirus software.
https://www.avast.com/antivirus

_________________
Searchable Archives: http://www.contesting.com/_topband - Topband Reflector

Reply via email to