Hi Teodor,

I was about to post a bug about it.
Before we fix this, here is a workaround to "clean" your model from validation 
errors and warnings: you can remove the validation errors and warnings by 
deleting the entries in the Eclipse problems view.
regards
raphaël


 Date du message : déc. 09 2009, 07:24 PM
 De : [email protected]
 A : [email protected]
 Copie : 
 Sujet : [Topcased-users] PB SysML: connecting FlowPorts
 
 Good morning everybody,
 
 I am currently trying to create a SysML model using in and out FlowPorts
 which i have been linking with connectors in my internal block diagrams.
 The trouble is that when i try to validate the model, I get the same error
 message for each connector between flowports.
 The message goes as follows:
 
 *Root diagnostic
   Delegation connector
 
'org.eclipse.uml2.uml.internal.impl.connectori...@1f9449a{platform:/resource/try_ports/ports_model.sysml#_yDeXSuSVEd6EBersqzHxhQ}'
 must only be defined between used interfaces or ports of the same kind.*
 
 Then I tried creating a very simple model containing only one block with one
 in and one out flowport, linked with a single connector in the internal
 block diagram.
 Unfortunately, I got the same error message concerning the only connector
 that i used.
 
 Can you please help me get rid of that error message so that my model
 becomes valid?
 
 Thank you in advance,
 Teodor
 
[ (pas de nom de fichier) (0.2 Ko) ]


Raphaël Faudou 

Innovation & method definition 
Critical systems

Atos Origin Integration


_______________________________________________
Topcased-users mailing list
[email protected]
http://lists.gforge.enseeiht.fr/mailman/listinfo/topcased-users

Reply via email to