This bug was fixed in the package mir - 0.21.0+16.04.20160330-0ubuntu1 --------------- mir (0.21.0+16.04.20160330-0ubuntu1) xenial; urgency=medium
[ Alberto Aguirre ] * New upstream release 0.21.0 (https://launchpad.net/mir/+milestone/0.21.0) - ABI summary: . mirclient ABI unchanged at 9 . mirserver ABI unchanged at 38 . mircommon ABI unchanged at 5 . mirplatform ABI unchanged at 11 . mirprotobuf ABI unchanged at 3 . mirplatformgraphics ABI unchaged at 8 . mirclientplatform ABI bumped to 5 . mirinputplatform ABI unchanged at 5 - Enhancements: . New display enumeration API . Added Android diagnostic tests to assist during porting to new devices . Added mir_demo_client_camera: a Video4Linux2 client - Bugs fixed: . Sometimes devices don't suspend - display turns back on immediately (LP: #1549701) . Mir crashed with exception 'failed to add sync point to command buffer' (LP: #1554635) . Mouse cursor is unusably slow in Unity 8 with a 1000Hz mouse (LP: #1539009) . Packaged mir_unit_tests binary is not suitable for general use (LP: #1547015) . [regression] Mir stops receiving input after a pause/resume cycle (LP: #1548989) . NBS (--nbuffers=0) causes software clients to crash with std::exception::what: Failed to mmap buffer 13, "Permission denied") (LP: #1550432) . Fullscreen clients freeze when using NBS with multiple monitors (LP: #1551536) . [ FAILED ] DisplayConfigurationTest.output_position_is_independent_of_ orientation (LP: #1552065) . The server-side use of MIR_SOCKET is confusing (LP: #1290345) . [regression] FTBFS with -DMIR_LINK_TIME_OPTIMIZATION=on -Duse_debflags=on (LP: #1350343) . Mir On X (mesa-x11) keeps receiving mouse movement events even when not focused (LP: #1528110) . x11 platform: mouse cursor moves strange (LP: #1546324) . Cross compiling to wily/vivid doesn't work (LP: #1549152) . Rendering stutters when a new client establishes a connection (LP: #1549359) . 'mir_demo_server --test-client' crashes (SIGSEGV) when client dies (LP: #1555620) . [testfail] CI failure: TestClientInput.client_input_config_request_ receives_all_attached_devices (LP: #1555708) . [regression] Mir FTBFS when MIR_ENABLE_TESTS=no (LP: #1556080) . Mir-on-X11 doesn't exit (until it gets an event) (LP: #1556210) . InputPlatformProbe.x11_platform_found_and_used_when_display_connection_ works breaks with old input drivers present (LP: #1543049) . [regression] MIR_CLIENT_PERF_REPORT is missing window/surface names (LP: #1546933) . Installed binaries fail to run with mir_demo_server --test-client XXXX (LP: #1556160) . mir_demo_server --test-client [mir_demo_client_scroll| mir_demo_client_flicker] fails (LP: #1556205) . The contents of debian/mir-demos.examples are out of date and useless (LP: #1557446) [ CI Train Bot ] * No-change rebuild. -- Alberto Aguirre <alberto.agui...@canonical.com> Wed, 30 Mar 2016 00:23:20 +0000 ** Changed in: mir (Ubuntu) Status: Confirmed => Fix Released -- You received this bug notification because you are a member of Ubuntu Touch seeded packages, which is subscribed to mir in Ubuntu. https://bugs.launchpad.net/bugs/1549701 Title: Sometimes devices don't suspend - display turns back on immediately Status in Canonical System Image: Confirmed Status in Mir: In Progress Status in Mir 0.21 series: Fix Committed Status in mir package in Ubuntu: Fix Released Status in unity-system-compositor package in Ubuntu: Confirmed Status in unity8 package in Ubuntu: Confirmed Bug description: current build number: 267 device name: krillin channel: ubuntu-touch/rc-proposed/bq-aquaris.en it happens also on arale. sometimes the screen lock timeout is not honoured and the devices don't suspend when the lock timeout expires (display doesn' t turn off) $ sudo powerd-cli list [sudo] password for phablet: System State Requests: Name: com.canonical.Unity.Screen, Owner: :1.14, State: 1 Steps to reproduce on arale: 1. Turn on the screen 2. Touch the circular touch button at the lower part of the device 3. Press/release the power button to turn off screen 4. Release the circular touch button Expected results: The screen turns off and further on/off cycles work properly Actual results: The screen stays on and attempts to turn it off fail The touchscreen is handling the circular button and emits a key down event. When turning the screen of the touch screen device is turned off too. Mir is not aware of the touchscreen being off. So meanwhile the repeat handling kicks in and emits key events. This makes USC turn the screen back on again. The touchscreen driver does not notice that the circular button is still held. So still no release event is sent. We could fix this by: - fixing the touchscreen driver to release any touch contacts or buttons pressed, when the device is turned off (something the bluetooth stack seems to do on some devices) - sidestep the problem by making usc only react to press events as a wake trigger and make repeat and release events only reset the inactivity timer - give mir the knowledge that the disabled output also disables the touchscreen (a connection we need to be aware of to get the mapping of touch screen coordinates onto scene coordinates right), hence remove the device and thus turn of any repeat key handling attached to that device. To manage notifications about this bug go to: https://bugs.launchpad.net/canonical-devices-system-image/+bug/1549701/+subscriptions -- Mailing list: https://launchpad.net/~touch-packages Post to : touch-packages@lists.launchpad.net Unsubscribe : https://launchpad.net/~touch-packages More help : https://help.launchpad.net/ListHelp