No, there should be a 'Do Once' button in the script editor.  If not, 
you don't have the latest version of otwincfg.

Scott

radionerd1 wrote:
>  
> 
> Thanks Scott,
> I have the latest fw, but still can't figure how to put "do once" into 
> the script. When I tried macro T" do once"  shows up like this, but 
> doesn't work:
> Alan
> 
> On GPS Fix
>  *Macro "Do Once"*
>   Exec "BEACON >NUVI-350 LOCKED ON TARGET"
>   End Block
> End Block
> --- In [email protected], Scott Miller <sc...@...> wrote:
>  >
>  > > I have been trying to send a one time beacon when I switch from profile
>  > > 1 to 2. The script wiki shows a "do once" command. I Tried "do once"
>  >
>  > Make sure you've got the latest firmware version loaded. DO ONCE is a
>  > new command.
>  >
>  > > On GPS Fix
>  > > Exec "BEACON >NUVI-350 LOCKED ON TARGET"
>  > > End Block
>  >
>  > This should be something like:
>  >
>  > On GPS Fix
>  > Do Once
>  > Exec "BEACON >NUVI-350 LOCKED ON TARGET"
>  > End Block
>  > End Block
>  >
>  > > On Interrupt
>  > > Exec "BEACON >LOST SKY"
>  > > End Block
>  >
>  > I don't think this is what you want. 'On Interrupt' is the IRQ input
>  > and has nothing to do with the GPS fix. You could use an 'else' on the
>  > 'On GPS Fix'.
>  >
>  > > If Profile 1
>  > > Exec "BEACON >LOCAL MODE WIDE1-1"
>  > > End Block
>  > > If Profile 2
>  > > Exec "BEACON >DX MODE, WIDE1-1,WIDE2-1"
>  > > End Block
>  >
>  > Again, you want 'Do Once' inside each IF block.
>  >
>  > Scott
>  >
> 
> 

Reply via email to