No, there should be a 'Do Once' button in the script editor. If not, you don't have the latest version of otwincfg.
Scott radionerd1 wrote: > > > Thanks Scott, > I have the latest fw, but still can't figure how to put "do once" into > the script. When I tried macro T" do once" shows up like this, but > doesn't work: > Alan > > On GPS Fix > *Macro "Do Once"* > Exec "BEACON >NUVI-350 LOCKED ON TARGET" > End Block > End Block > --- In [email protected], Scott Miller <sc...@...> wrote: > > > > > I have been trying to send a one time beacon when I switch from profile > > > 1 to 2. The script wiki shows a "do once" command. I Tried "do once" > > > > Make sure you've got the latest firmware version loaded. DO ONCE is a > > new command. > > > > > On GPS Fix > > > Exec "BEACON >NUVI-350 LOCKED ON TARGET" > > > End Block > > > > This should be something like: > > > > On GPS Fix > > Do Once > > Exec "BEACON >NUVI-350 LOCKED ON TARGET" > > End Block > > End Block > > > > > On Interrupt > > > Exec "BEACON >LOST SKY" > > > End Block > > > > I don't think this is what you want. 'On Interrupt' is the IRQ input > > and has nothing to do with the GPS fix. You could use an 'else' on the > > 'On GPS Fix'. > > > > > If Profile 1 > > > Exec "BEACON >LOCAL MODE WIDE1-1" > > > End Block > > > If Profile 2 > > > Exec "BEACON >DX MODE, WIDE1-1,WIDE2-1" > > > End Block > > > > Again, you want 'Do Once' inside each IF block. > > > > Scott > > > >
