Hi Guys, I'm not sure if anyone has sat down and measured what Power Output was created by each "SETLEVEL" setting on the T2-301, but since I have a need to limit ERP to 25 Watts, I decided to sit down and do just that.
A Summary writeup is here: http://hal.g7iii.net/wordpress/?p=118 Power levels were measured at SETLEVELs of 11, 17, 22, 27, 31, 34, 41, 50, 55, 62, 66, 70, 75, 99. They were picked according to the power output I was trying to achieve. The T2-301 was being fed 13.8 volts. If anyone wants the raw data, holler, and I can post it, or send it privately (it's only a spreadsheet) 73s Iain