Hi Guys,

I'm not sure if anyone has sat down and measured what Power Output was created 
by each "SETLEVEL" setting on the T2-301, but since I have a need to limit ERP 
to 25 Watts, I decided to sit down and do just that.

A Summary writeup is here: http://hal.g7iii.net/wordpress/?p=118

Power levels were measured at SETLEVELs of 11, 17, 22, 27, 31, 34, 41, 50, 55, 
62, 66, 70, 75, 99. They were picked according to the power output I was trying 
to achieve. The T2-301 was being fed 13.8 volts.

If anyone wants the raw data, holler, and I can post it, or send it privately 
(it's only a spreadsheet)


73s

Iain