I've sent a note to the contract manufacturer to make sure those leads 
get cut off flush in the future, and I'll inspect them as they come in.

This didn't get caught in testing because RX is tested while the board 
is on a test fixture, and not installed in the case.  The final 
post-assembly test just checks that it powers on and that the LEDs and 
DC power jack are OK.  The assembled test units I've been using had the 
lead cut short enough, apparently.

Sorry about that, and thanks for the catch.

Scott

n0rxd wrote:
>  
> 
> 
> That was my problem exactly - the long lead on the crystal was shorted 
> to the case. I bent it out of the way and now it's working like a champ, 
> thanks.