A local group just got a T2-135 replacement board. The new board has 
Tracker2 Build 55076 and the other 7 units have Tracker2 Build 54680.

I got a call late last night that the replacement board was not working 
without the computer connected. As soon as they disconnected the computer 
the system stopped transmitting. The PROFILE command issued locally returned 
2 and when I sent it remotely it returned 1. I cannot be certain the 
computer was still connected when I sent the command remotely (they said it 
was). There was some question on my part if they had disconnected it.

In any event the problem was isolated to the T2-135 using Profile 2 for some 
reason when the computer was connected and then switching to Profile 1 when 
it was disconnected. What triggers a profile change when a computer is 
connected or not connoted to the DB9 on the DR-135T?

They said when typing PROFILE 1 it returned a ~ and a block on the screen. 
Since I could not see it I cannot validate the description of the problem.

I had them type CONFIG and they said it returned 0. The manual indicates you 
can set 1 or 2 for the CONFIG, so this was puzzling. CONFIG 2 seemed to hold 
what they programmed so I had them issue CONFIG 1 and enter their 
configuration. This was all done manually without the config software 
utility. Once they performed this action the T2-135 behaved when the 
computer was disconnected and then the weather station was connected.

I am strapped for time with work to experiment/debug/research this behavior 
at the moment so I wonder if anybody can provide some insight.


Thanks,
Tim - N8DEU



Reply via email to