Joe,

We recently posted full details of South Korea's requirements in comparison to 
the EU inc test levels etc.

You can see the tables and details at
 http://www.approvalspecialists.com/news.html#koreanemc

Best,
Martin.


  ----- Original Message ----- 
  From: [email protected] 
  To: [email protected] ; [email protected] 
  Sent: Saturday, March 17, 2001 4:36 AM
  Subject: Korean immunity requirements


  Dear All: 

  It is my understanding that South Korea has adopted a set of EMC immunity 
  requirements that are similar, but not identical, to the ones that the EU 
  imposes.  I believe that the scope of the requirements includes ESD, radiated 
  RF immunity, EFT, surge, and voltage drops. 

  So far, I have only heard verbal references to these requirements, but I 
  would like to get more definitive information.  Can anyone in the group help 
  me with the following questions? 

  1) What are the official standards (publishing entity and standard numbers) 
  for EMC immunity? 

  2) What types of equipment fall within the scope of these requirements?  (My 
  particulat interest is telecom equipment, both TTE and central office). 

  3) Are the immunity requirements mandatory at this time or will they be 
  phased in at a later date? 

  4) Is there a way to get English translations of the requirements and test 
  procedures? 

  5) What test labs are certified to perform the tests? 


  Thanks for any assistance you can provide. 


  Joe Randolph 
  Telecom Design Consultant 
  Randolph Telecom, Inc. 
  781-721-2848 
  http://www.randolph-telecom.com 

Reply via email to