I'm trying to find the requirements of DTMF tone detection for various
countries.
I have the requirements for Australia ( shown below ). Can someone help me
with the other countries please.
I believe there are no mandatory requirements for DTMF detection for Europe
and USA, please correct me if I'm wrong.
  
Australian Requirements : AS/ACIF S003 : 1999

If  DTMF signal detection is provided, the following requirements are to
apply:
(a) DTMF signals that are within the following limits shall be
recognised:
(i) Frequency tolerances of ± (1.5% + 2 Hz) from the nominal
frequency as specified in ACA Technical Standard 002 [2].
(ii) A total RMS power level between 0 dBm and -20 dBm with
a maximum difference between the high frequency tone and
the low frequency tone power of +4 dB to -4 dB relative to
that of the low frequency tone.
(iii) A break between tone signals of 70 ms and greater, as an
interdigital pause.
(iv) A valid tone signal of 40 ms duration and greater.

Now, what are these limits for :  USA, Europe (especially UK), South Africa,
Korea and Singapore

Thanks very much in advance.