Jim,

The Australians require supplementary insulation because the NT1s installed
there do not provide isolation between the U and the S/T interfaces so the
S/T is classed as TNV not SELV. Look in the RCIC web site in the EMC-PSTC
discussion at uc.com/compliance_engineering/pstc_db.htm for more
information.

Dick Shultz

>Supplementary insulation
>
>Best regards
>Barry Singleton
>Approvals Specialist email:[email protected]
>Securicor 3net Limited
>Ringway House Bell Road
>Daneshill  Basingstoke
>Hants  RG24 8FB  UK
>Tel: 44 (0)1256 792174
>Fax: 44 (0)1256 840429
>-------------
>Original Text
>From: Jim Wiese <[email protected]>
>Organization: ADTRAN, Inc.
>
>Does anyone know what the signal tranformer requirements for an
>ISDN S/T interface in Australia.
>
>The assumption is that the power supply to the terminal adapter meets all
>applicable safety requirements.
>
>What I'm basically looking for are the Creepage, Clearance and
>insuluation category requirements.
>
>Thanks,
>
>Jim Wiese
>ADTRAN, Inc.