Hi Gang,
     
We are currently building another OATS and are looking into the most 
cost & time effective way of achieving a uniform conductive groundplane 
without using mesh. Does anyone have experience with using galvanised 
metal sheet, and if so, the best method to join the sheets together 
(silver solder, braze etc), bearing in mind temperatures >45deg C in 
summer.
     
Alternatively has anyone had success with conductive coating or paint 
over concrete ?
     
Any thoughts would be appreciated.
     
Best Regards.
-- 
Martin Garwood, Manager, Austest Laboratories
4/87 Reserve Road Artarmon NSW 2064 AUSTRALIA
ph: 61-2-94374500  fax: 61-2-94374600
http://www.austest.com.au

Reply via email to