From: Heiko Kuehling/Jpn/TUV
  <[email protected]>
Subject: CTI Tracking Index

Hello Treckers,
I have a question regarding the tracking index. The tracking index will be 
"measured" according to IEC 112. The test condition for applied is given with a 
minimum thickness of 3mm . (If the sample has a thickness less than 3mm, they 
shall bestapled up to 3mm in order to garantee the comparebility of 
testresults). I checked the yellow book from UL and usually plastic materials 
under 3mm are not tested for CTI. 
Can we apply a higher CTI - value to reduce creepage distances for materials 
with less than 3mm?

Reply via email to