Hello,

Is there anyone actually using tests for emc acc to EN 61000-4-6
having to deal with equipment with a lot of cables ?

I 'm having the problem of  applying CDN's to more then 10 cables
(of similar type) , and want to evaluate if and how we have to
decide to connect 10 CDNS to 10 cables, or to a subset of these.

!0 cables can be connected , but a following appartus might be equipped
with 25 ports . Where to stop . The problem is not to apply current
injection
to all cables at the same time (that can be done using the EM-clamp), but
to the 150
Ohms loading requirement. I have the feeling that this might be done using
a second ferrite clamp. Anyone having experience with this.
I am a new subscriber to this list, and do not know if this topic was
discussed before.
If there is some form of archive, let me know.

Thanks in advance


Ing. Gert Gremmen
[email protected]
http://www.cetest.nl

----------------------------------------------------------------------------
----------------------------
ce-test , qualified testing
Electro Magnetic Compatility - Electrical Safety
Compliance testing, Education and Workhops, Consultancy
Bezoek de Nationale Electronica WeB Ring (Dutch only)
http://www.cetest.nl/e-ring.htm

----------------------------------------------------------------------------
----------------------

Reply via email to