For groups 1 and 2, Class B QP limit = -19.1[log(f,MHz)]+ 50.3
Avg limit = -19.1[log(f,MHz)] + 40.3 JP -----Original Message----- From: [email protected] [mailto:[email protected]] Sent: Monday, September 28, 1998 2:11 PM To: [email protected] Subject: CISPR 11 CONDUCTED EMISSION FORMULA? I am looking for the formula used to tell the limit of compliance when doing CISPR 11 group 1 &2 Conducted testing. The slop section of 0.15MHz. to 0.5MHz. for class B testing. I have this in a per MHz chart but I now find that a formula would be much less cumbersome.... Any help would be greatly appreciated! Michael Sundstrom KTL Dallas 802 North Kealy Lewisville Texas, 75057-3136 fax: 972.436.2667 phone: 972.436.9600 ext 303 Webpage http://www.icomply.com [email protected] "These are my views not necessarily those of my employer"