On Nov 18, Daniel Monjar ([EMAIL PROTECTED]) wrote: > Mandrake 9.2 on Intel > > (scsi0:A:0): 160.000MB/s transfers (80.000MHz DT, offset 127, 16bit) > (scsi0:A:5): 10.000MB/s transfers (10.000MHz, offset 15) > (scsi0:A:6): 160.000MB/s transfers (80.000MHz DT, offset 63, 16bit) > Vendor: FUJITSU Model: MAJ3182MP Rev: 5508 > Type: Direct-Access ANSI SCSI revision: 04 > Vendor: Quantum Model: DLT4000 Rev: D069 > Type: Sequential-Access ANSI SCSI revision: 02 > Vendor: IBM Model: DDYS-T18350N Rev: S93E > Type: Direct-Access ANSI SCSI revision: 03 > > > I've had to add a quantum SCSI tape to the same adapter that handles my > SCSI disks. Is the tape drive slowing down the disks in any way? Ages ago > when I was configuring SCSI DEC systems (VMS 6.2) I was cautioned about > mixing slow and fast devices on the same bus, because transfer would happen > at the speed of the slow device. Still true?
>From the manual for the Adaptec 2940U2W adaptor: "We recommend keeping your Ultra2 hard disk drives separate from your non Ultra2 peripherals. Connecting a non Ultra2 hard disk drive to the Ultra2 connector on the SCSI Card 2940U2W causes the Ultra2 SCSI segment of the SCSI bu s to drop down to Ultra SCSI performance levels (40 MBytes/sec)." For this reason, I bought a second adaptor for the SCSI CD-R that I put into a machine with SCSI Ultra2 drives. -- Neil Roeth -- TriLUG mailing list : http://www.trilug.org/mailman/listinfo/trilug TriLUG Organizational FAQ : http://trilug.org/faq/ TriLUG Member Services FAQ : http://members.trilug.org/services_faq/ TriLUG PGP Keyring : http://trilug.org/~chrish/trilug.asc