Dear Javier,
I would recommend looking at the references cited in the mathematical
description of Type 180 (Volume 5, section 5.2.9). This component
started as a model for a PhD thesis in the Norwegian University of
Science and Technology.
Best regards,
Diego
javier mota wrote:
halo, I am javier mota from 3i-ingenieria, madrid
I am working with pv model 180 e
I have a book wich calculate Vocc(voltage open circuit ) as
Vocc=vocc, nominal+MUVOC*(Tcell-25)
Tcell=tambient+0.3*G, where G=radiation
I supose trnsys model is more accurate.
The problem is that Vocc with my book formule predict that for our
arrangement, series 25 panels,
woluld be on the limit of what may be admisible by the panles and
inverter.
But TRNSYS predict Vocc values no so critical, values are lower.
Must I think that the formule of my book is rude and so i mus be quiet
with tRNSYS prediction of Vocc
Can I found some internet direction with information about TRNSYS
model for PV.
Thanks in advance
_________________________________________________________________
Acepta el reto MSN Premium: Correos más divertidos con fotos y textos
increíbles en MSN Premium. Descárgalo y pruébalo 2 meses gratis.
http://join.msn.com?XAPID=1697&DI=1055&HL=Footer_mailsenviados_correosmasdivertidos
_______________________________________________
TRNSYS-users mailing list
[email protected]
https://www.cae.wisc.edu/mailman/listinfo/trnsys-users
--
Diego A. Arias
TRNSYS Coordinator
Solar Energy Laboratory
University of Wisconsin - Madison
1500 Engineering Drive
Madison, WI 53706
_______________________________________________
TRNSYS-users mailing list
[email protected]
https://www.cae.wisc.edu/mailman/listinfo/trnsys-users