Jochen, I have not run into the problem that you describe. The "Time inconsistency" error might be due to a rounding problem. If you are using a time step that is represented by an infinitely repeating decimal number of hours (5 min = 0.41666666.... hours for example) then the Studio may be writing the time step as a truncated decimal. Why you would have a different result when running from the Studio versus running from TRNEdit is a mystery since as soon as a simulation is launched, the interface (whether Studio or TRNEdit) is totally irrelevant and all that matters is the text in the *.dck file. I would suggest sending the input file and *.bui to your distributor to see if they can help sort out the problem. Kind regards, David
At 04:40 12/5/2006, Jochen Doell wrote: >Hello, > >I am trying to set up a parametric studie in TRNSYS16. >My deck works perfectly in the simulation studio. But after exporting a >*.dck file, running TRNEDIT and defining my table all the simulations >quit after a few hours (sim-time). Reason: Fatal Error, time >inconsistency between data reader and solar radiation processor. >This only happens in TRNEDIT, not in the simulation studio. And, >furthermore, my building connections are wrecked after using TRNEDIT, i >always have to copy my bui-file from the backup back to the folder. > >Seems to be a bug, or does anyone have a solution? > >Best regards and thanks in advance, >Jochen > >-- >__________________________________________________ >Jochen Döll / Diplomand > >Dept. Thermally Active Materials and Solar Cooling > >Fraunhofer-Institut für Solare Energiesysteme >Heidenhofstrasse 2, 79110 Freiburg, Germany > >+49 (761) 4588 5456 >[EMAIL PROTECTED] >www.ise.fhg.de > >_______________________________________________ >TRNSYS-users mailing list >TRNSYS-users@engr.wisc.edu >https://www.cae.wisc.edu/mailman/listinfo/trnsys-users **************************************************************************************** Thermal Energy System Specialists (TESS), LLC David BRADLEY 2916 Marketplace Drive - Suite 104 Partner Madison, WI 53719 Phone: (608) 274-2577 USA Fax: (608) 278-1475 E-mail: [EMAIL PROTECTED] Web Pages: http://www.tess-inc.com and http://www.trnsys.com "Providing software solutions for today's energy engineering projects" **************************************************************************************** _______________________________________________ TRNSYS-users mailing list TRNSYS-users@engr.wisc.edu https://www.cae.wisc.edu/mailman/listinfo/trnsys-users