Dear Guillaume, Please go to Manual 7-"TRNEdit: Editing the input file and creating distributable applications", section 7.6.9 "The EQUATIONS Statement". It explains the available mathematical functions.
Sometimes it is easier to post-process the results in a spread sheet than to try to find the right combination of IF functions that will give you the result that you want. Best regards, Diego guillaume renaud wrote: > Thanks Jeff, > > Actually I didn't find any TRNSYS equation command's guide or manuel... > > I can tell you what's my problem, you'll certainly understand how > novice I am... ; > > I'm using the TMY2 Dry Bulb temperature in a first equation > calculator, in order to get new mensually outdoor temperature (with a > simple equation needed for my project, integrated in the calculator) = > No problem for it. > But the matter is that I can't get a good Output file for printed > results on type 65d, and on type 25a. And so I can't use the solution > afterward.. and I think it's because of the number of Input >10... > > Then, I'm trying to transform those 12 Outputs I get (average for each > month from my first calculator), in another new calculator to get new > hourly temperatures for the whole year.. > Then I need to give conditions in time, as ; [take JanTemperature from > hour 0 to hour 744], [take FevTemperature from hour 745 to hour 1416], > etc... > > Well.. I hope being clear enough.. and anyway I guess having the good > guide should be nice enough for me.. > > guillaume. > > */Jeff Thornton <[EMAIL PROTECTED]>/* a écrit : > > "I`m looking for any good tool giving complete information about the > calculator, for the use of [NEW EQUATION] within simulation > studio...(I > trying to put conditions in my equations, and I didn't find > enagh explanation in the manuel...)" > > Why don't you give us an example of the conditions you'd like to > use and > we'll show you how to do it using TRNSYS equations. This might provide > helpful to other users as well. There is a nice description of the > TRNSYS > equation commands in the manual (not the manual for the studio). > > Jeff > > Jeff Thornton > President - TESS, LLC > > 2916 Marketplace Drive - Suite 104 > Madison WI 53719 USA > > Phone: 608-274-2577 > Fax: 608-278-1475 > E-mail: [EMAIL PROTECTED] > Web: www.tess-inc.com > > > ------------------------------------------------------------------------ > Découvrez une nouvelle façon d'obtenir des réponses à toutes vos > questions ! Profitez des connaissances, des opinions et des > expériences des internautes sur Yahoo! Questions/Réponses > <http://fr.rd.yahoo.com/evt=42054/*http://fr.answers.yahoo.com>. > ------------------------------------------------------------------------ > > _______________________________________________ > TRNSYS-users mailing list > [email protected] > https://www.cae.wisc.edu/mailman/listinfo/trnsys-users > -- Diego A. Arias TRNSYS Coordinator Solar Energy Laboratory University of Wisconsin - Madison 1500 Engineering Drive Madison, WI 53706 _______________________________________________ TRNSYS-users mailing list [email protected] https://www.cae.wisc.edu/mailman/listinfo/trnsys-users