Hi Fuqiao,
I just set the cooling power in a project of mine to a variable value and it works just fine. Did you connected Q_HEATING to the correct input? Regards, Met vriendelijke groet, Jan-Willem van Laer, Assistent Projectleider Cauberg-Huygen Raadgevende Ingenieurs BV Bezoekadres: Boterdiep 48, 3077 AW Rotterdam Postadres: Postbus 9222, 3007 AE Rotterdam Telefoon: 010 - 4257444 Fax: 010 - 4254443 E-mail: [EMAIL PROTECTED] Web: www.chri.nl KvK-nummer: 14623897 Disclaimer: Op deze e-mail is een disclaimer van toepassing: A disclaimer is applicable to this e-mail, please refer to: <http://www.chri.nl/emaildisclaimer> http://www.chri.nl/emaildisclaimer _____ Van: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] Verzonden: donderdag 3 januari 2008 11:46 Aan: [EMAIL PROTECTED]; trnsys-users@engr.wisc.edu Onderwerp: Re: [TRNSYS-users] type56 Bugs? hi, all in type 56, in cooling/heating type manager, you can not set the cooling/heating power as input variable, they do not work! however, if you use unlimited power or constant, it works pretty well ! Can anybody try this and tell me why? thank you in advance! Best wishes! Fuqiao Wang Sustainable Consulting Engineer FULCRUM CONSULTING London: Tel: +44 (0)20 7520 1300/1305 Edinburgh: Tel: +44 (0)131 226 0220 Spain: Tel: +34 98 5195989 mailto:[EMAIL PROTECTED] www.fulcrumfirst.com _____ From: Timo Sengewald [mailto:[EMAIL PROTECTED] Sent: 2008年1月3日 10:33 To: trnsys-users@engr.wisc.edu Subject: [TRNSYS-users] type56 Bugs? No idea what this may be. It would be helpful if you sent your .bui and .dck to the list. Perhaps some body else can have a look at it, too. Timo _____ Von: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] Gesendet: Donnerstag, 3. Januar 2008 11:25 An: Timo Sengewald Betreff: RE: [TRNSYS-users] type56 Bugs? hi, Timo the room temperature does not change when you are using this type as shown. (I mean no matter how big input value you gave. the room temperature still went upto 40 even you set the temperature at 26 deg C, however, if a constant being inputted, it works pretty well! ) (the similar things happens in heating type mode! ) thank you for your quick response. Regards Fuqiao Wang Sustainable Consulting Engineer FULCRUM CONSULTING London: Tel: +44 (0)20 7520 1300/1305 Edinburgh: Tel: +44 (0)131 226 0220 Spain: Tel: +34 98 5195989 mailto:[EMAIL PROTECTED] www.fulcrumfirst.com _____ From: Timo Sengewald [mailto:[EMAIL PROTECTED] Sent: 2008年1月3日 10:07 To: Fuqiao Wang Subject: AW: [TRNSYS-users] type56 Bugs? Fuqiao, what in detail is the problem? All seems fine in the screen shot. What happens when you run the simulation? Timo BLS Energieplan GmbH i. A. Timo Sengewald Elsenstraße 106 D-12435 Berlin Tel.: +49 30 53 32 81-0 Fax: +49 30 53 32 81-40 ____________________________________________________ BLS Energieplan GmbH Sitz der Gesellschaft: Berlin Geschäftsführer: Christoph Lange, Wolfgang Sturm Registergericht: Amtsgericht Berlin-Charlottenburg, HRB-Nr. 32021 _____ Von: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] Gesendet: Donnerstag, 3. Januar 2008 10:38 An: trnsys-users@engr.wisc.edu Betreff: [TRNSYS-users] type56 Bugs? Dear All Happy new Year! please help me with my problem as attached. in Type 56, when a cooling type being set as an input limited power, it does not work. I 've tried this power by using a constant, or unlimited power, both work fine. what's wrong with it? Thank you in advance. Best wishes Fuqiao Wang Sustainable Consulting Engineer FULCRUM CONSULTING London: Tel: +44 (0)20 7520 1300/1305 Edinburgh: Tel: +44 (0)131 226 0220 Spain: Tel: +34 98 5195989 mailto:[EMAIL PROTECTED] www.fulcrumfirst.com -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] Sent: 2008年1月2日 18:03 To: trnsys-users@engr.wisc.edu Subject: TRNSYS-users Digest, Vol 37, Issue 1 Send TRNSYS-users mailing list submissions to trnsys-users@engr.wisc.edu To subscribe or unsubscribe via the World Wide Web, visit https://www.cae.wisc.edu/mailman/listinfo/trnsys-users or, via email, send a message with subject or body 'help' to [EMAIL PROTECTED] You can reach the person managing the list at [EMAIL PROTECTED] When replying, please edit your Subject line so it is more specific than "Re: Contents of TRNSYS-users digest..." Fulcrum Consulting is proud to be a Founding Member of the UK Green Building Council. To find out more visit http://www.ukgbc.org ******************* email confidentiality notice ************************* This message is intended for the addressee recipient only. It is private and confidential. If you have received this message in error, please notify the sender immediately and remove it from your system. If you are not the intended recipient you must not use, disclose, distribute, copy, print or rely on this email. Fulcrum First Ltd Incorporated in England and Wales with Registered Number: 03401753. Registered Office: 62-68 Rosebery Avenue, London EC1R 4RR ************* Fulcrum First Ltd trading as Fulcrum Consulting *************
<<image001.gif>>
_______________________________________________ TRNSYS-users mailing list TRNSYS-users@engr.wisc.edu https://www.cae.wisc.edu/mailman/listinfo/trnsys-users