The minimum amount of PCRs a TPM must have is 16. Does yours have this
such PCR? Just tested on mine that has 24 and the it passed fine.

Thanks,
Rajiv Andrade
IBM LTC Security Development

On Wed, 2009-11-25 at 17:56 +0800, adrian golding wrote:
> hi, i ran the sample code from testsuites on sealing and it worked
> alright.
> but when i changed the PCR to be sealed to, to PCR 17 (instead of
> PCR8) by doing this:
> result = Tspi_PcrComposite_SetPcrValue( hPcrComposite, 17, 20,
> rgbPcrValue );
> 
> it does not work and returns TSS_E_INTERNAL_ERROR. i am wondering if
> it is because of the seal function expecting a v1.1 TPM or something?
> I am currently using trousers v3.1.  Anybody know why? 
> 
> -adrian
> 
> 
> 
> ------------------------------------------------------------------------------
> Let Crystal Reports handle the reporting - Free Crystal Reports 2008 30-Day 
> trial. Simplify your report design, integration and deployment - and focus on 
> what you do best, core application coding. Discover what's new with
> Crystal Reports now.  http://p.sf.net/sfu/bobj-july
> _______________________________________________ TrouSerS-users mailing list 
> [email protected] 
> https://lists.sourceforge.net/lists/listinfo/trousers-users


------------------------------------------------------------------------------