On 25. Jul 2022, at 10:42, Michael Welzl <[email protected]> wrote: > > There is overload, which is undesirable; there is also underload, which is no > less desirable. In between, there is an ideal state that CC algorithms aim > for: 100% utilization at the bottleneck but no adverse effects for anyone. > I would call this “saturation” or “full utilization” or something like that, > but not “congestion”.
So this is all about “load control”? Proper sharing of capacity is the other part of the function. Grüße, Carsten